9.4.2 Fixing System Error Code
0013-8530
Color iR C3380G / Color iR C2880G / Color iR C3380i / Color iR C3380 / Color iR C2880i / Color iR C2880 / iR C3480 / iR C3480i / iR C3080 / iR C3080i / iR
C2550
T-9-11
Code
Description
Corrective action
E001
Fixing high temperature error
0000 Condition
The reading of the main thermistor is 260 deg C or more.
Cause
The main thermistor is faulty. The DC PCB is faulty.
- Replace the fixing sleeve unit (main thermistor).
- Replace the DC controller PCB. *1
0001 Condition
The reading of the sub thermistor is 290 deg C or more.
Cause
The sub main thermistor is faulty. The DC PCB is faulty.
- Replace the fixing sleeve unit (sub thermistor).
- Replace the DC controller PCB. *1
0002 Condition
The safety circuit (of the DC controller) has detected a high temperature error
(about 260 deg C or more).
Cause
The thermal switch is faulty. The low-temperature power supply PCB is
faulty. The DC PCB is faulty.
Replace the DC controller PCB. *1
E003
Fixing low temperature error
0000 Condition
In 20 sec after the fixing heater has gone on, the reading of the main thermistor
is 120 deg C or less.
Cause
The main thermistor is faulty. The DC controller is faulty. The connector has
poor contact, or the harness is faulty.
- Replace the fixing sleeve unit (main thermistor).
- Replace the DC controller PCB. *1
0001 Condition
In the course of printing temperature control, the reading of the sub thermistor
is 80 deg C or less for 2 sec or more.
Cause
The sub thermistor is faulty. The DC controller PCB is faulty. The connector
has poor contact, or the harness is faulty.
- Replace the fixing sleeve unit (sub thermistor).
- Replace the DC controller PCB. *1
0002 Condition
During initial rotation, the reading of the main thermistor is 50 deg C or less
0.2 sec after the start of temperature control.
Cause
The DC controller PCB is faulty. The connector has poor contact, or the
harness is faulty.
- Replace the fixing sleeve unit (main thermistor).
- Replace the DC controller PCB. *1
E004
Thermistor is not connected
0000 During walm-up rotation, the thermistor connection signal (FUSER CNCTX)
is open.
- Confirm the cable connection
- Replace the cable exchange, and established
- Replace the fixing unit
- Replace the DC controller PCB.
E009
Error in pressure/release of fixing film unit
0001 In case that the output of fixing automatic pressure phase sensor is not changed
although rotating/reversing the fixing motor
- Check the pressure/release mechanism. Check the connection of the
connector.
- Replace the motor.
E808
Low-voltage power supply circuit fault (zero-cross error)
0000 The low-voltage power supply circuit fault (zero-cross error)
Cause
The low-voltage power supply PCB is faulty. The DC controller PCB is faulty.
- Replace the low-voltage power supply PCB.
- Replace the DC control PCB.
E840
Fan shutter error
0000 Fan shutter open/close operation Error
Cause
Abnormal rotation of the fan shutter motor
Defect of the fan shutter position sensor
Defect of the fan shutter home position error
Defect of the DC controller PCB
- Replace the fan shutter motor
- Replace the fan shutter position sensor
- Replace the fan shutter home position sensor
- Replace the DC controller PCB
Summary of Contents for CiRC2550
Page 2: ......
Page 27: ...Chapter 1 Introduction ...
Page 28: ......
Page 47: ...Chapter 1 1 18 F 1 14 ON OFF ON OFF ...
Page 70: ...Chapter 1 1 41 5 Turn on the main power switch ...
Page 79: ...Chapter 2 Installation ...
Page 80: ......
Page 85: ...Chapter 2 2 3 Not available in some regions ...
Page 134: ...Chapter 3 Basic Operation ...
Page 135: ......
Page 137: ......
Page 143: ...Chapter 4 Main Controller ...
Page 144: ......
Page 152: ...Chapter 4 4 6 F 4 6 CPU HDD ROM access to the program at time of execution ...
Page 171: ...Chapter 5 Original Exposure System ...
Page 172: ......
Page 203: ...Chapter 6 Laser Exposure ...
Page 204: ......
Page 206: ......
Page 220: ...Chapter 7 Image Formation ...
Page 221: ......
Page 277: ...Chapter 8 Pickup Feeding System ...
Page 278: ......
Page 282: ......
Page 336: ...Chapter 9 Fixing System ...
Page 337: ......
Page 339: ......
Page 357: ...Chapter 10 Externals and Controls ...
Page 358: ......
Page 362: ......
Page 366: ...Chapter 10 10 4 F 10 2 F 10 3 FM1 FM2 FM5 FM8 FM11 FM4 FM3 FM6 FM7 FM9 FM10 ...
Page 375: ...Chapter 10 10 13 F 10 10 2 Remove the check mark from SNMP Status Enabled ...
Page 376: ...Chapter 10 10 14 F 10 11 ...
Page 402: ...Chapter 11 MEAP ...
Page 403: ......
Page 405: ......
Page 452: ...Chapter 12 RDS ...
Page 453: ......
Page 455: ......
Page 464: ...Chapter 13 Maintenance and Inspection ...
Page 465: ......
Page 467: ......
Page 469: ...Chapter 13 13 2 F 13 1 8 9 1 2 3 3 5 6 7 10 11 12 13 14 4 ...
Page 474: ...Chapter 14 Standards and Adjustments ...
Page 475: ......
Page 477: ......
Page 485: ......
Page 486: ...Chapter 15 Correcting Faulty Images ...
Page 487: ......
Page 495: ...Chapter 15 15 4 F 15 2 COLOR M 1 COLOR Y C K 0 ...
Page 569: ...Chapter 15 15 78 F 15 82 J102 J107 J103 J108 J101 J109 J106 J112 J115 J113 J114 J104 J105 ...
Page 570: ...Chapter 16 Self Diagnosis ...
Page 571: ......
Page 573: ......
Page 600: ...Chapter 17 Service Mode ...
Page 601: ......
Page 603: ......
Page 712: ...Chapter 18 Upgrading ...
Page 713: ......
Page 715: ......
Page 746: ...Chapter 19 Service Tools ...
Page 747: ......
Page 749: ......
Page 752: ...APPENDIX ...
Page 774: ......