CHAPTER 4 SERVICE MODE
4-52
DENS
SGNL-Y
SGNL-M
SGNL-C
REF-Y
REF-M
REF-C
SIGG-Y
SIGG-M
SIGG-C
RGAIN-K
D-Y-TRGT
D-M-TRGT
D-C-TRGT
PTOFST-Y
PTOFST-M
PTOFST-C
PTOFST-K
D-REF-Y
D-REF-M
D-REF-C
D-REF-K
D-REF-4
concentration signal of Y toner during INIT
for ATR control
concentration signal of M toner during INIT
for ATR control
concentration signal of C toner during INIT
for ATR control
concentration reference signal of Y toner
during INIT for ATR control
concentration reference signal of M toner
during INIT for ATR control
concentration reference signal of C toner
during INIT for ATR control
gain for concentration reference signal of Y
toner during ATR control
gain for concentration reference signal of M
toner during ATR control
gain for concentration reference signal of C
toner during ATR control
gain for concentration reference signal of Bk
toner during toner concentration control
present value of the concentration target of
Y toner during ART control
present value of the concentration target of
M toner during ART control
present value of the concentration target of C
toner during ART control
correction value (%) for the laser output of
Y toner during ART control
correction value (%) for the laser output of
M toner during ART control
correction value (%) for the laser output of C
toner during ART control
correction value (%) for the laser output of
Bk toner during ART control
reference signal value for the concentration
sensor of Y toner in relation to the reflection
intensity of light from the photosensitive
drum (upon initialization)
reference signal value for the concentration
sensor of M toner in relation to the reflection
intensity of light from the photosensitive
drum (upon initialization)
reference signal value for the concentration
sensor of C toner in relation to the reflection
intensity of light from the photosensitive
drum (upon initialization)
reference signal value for the concentration
sensor of Bk toner in relation to the
reflection intensity of light from the
photosensitive drum (upon initialization)
reference signal value for the concentration
sensor of all toners in relation to the
reflection intensity of light from the
photosensitive drum (upon initialization)
0 to 1023
0 to 1023
0 to 1023
0 to 1023
0 to 1023
0 to 1023
0 to 255
0 to 255
0 to 255
0 to 255
0 to 1023
0 to 1023
0 to 1023
-127 to +128
-127 to +128
-127 to +128
-127 to +128
0 to 1023
0 to 1023
0 to 1023
0 to 1023
0 to 1023