CHAPTER 4 IMAGE PROCESSING SYSTEM
COPYRIGHT © 1999 CANON INC. CANON CLC1120/1130/1150 REV.0 MAR. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
4-17
A. Electrical Parts
1. Removing the CCD Unit
1) Disconnect the power plug.
2) Remove the copyboard glass.
3) Remove the four screws [1], and detach
the lens mount cover [2].
Figure 4-501
4) Remove the nine screws [3], and detach
the laser unit cover (front) [4]. (200V
model only)
5) Remove the two screws [5], and detach
the laser unit cover (rear) [6]. (200V
model only)
6) Remove the two screws [7], and detach
the two CCD unit retaining spring [8].
7) Remove the grounding plate [9].
Figure 4-504
Figure 4-502
Figure 4-503
8) Lift the CCD unit, and disconnect the two
connectors [10].
[1]
[2]
[1]
[5]
[5]
[6]
[3]
[3]
[3]
[4]
[7]
[9]
[8]
[8]
[7]
[10]