CHAPTER 5 LASER EXPOSURE SYSTEM
5-2
COPYRIGHT © 1999 CANON INC. CANON CLC1120/1130/1150 REV.0 MAR. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
The major items of control and functions of the laser exposure system are as follows:
1.
Laser Exposure System Control
Optimum intensity control to suit the surface potential of the drum
2.
Laser Scanning Method
Beam spot scanning
3.
Synchronization Control
By the BD signal in main scanning direction
By the ITOP signal in sub scanning direction
4.
Laser Scanner Control
Constant rotation speed
B. Sequence of Operations (laser exposure system)
Figure 5-102 A4/LTR, 2 Copies, Full Color, Direct, Cassette 1
1
2
3
4
5
6
7
8
Y
M
C
K
Y
M
C
K
DSRDY
INTR
COPY
LSTR
1
2
3
4
5
6
7
8
Copy Start key ON
Photosensitive drum revolution
Transfer drum revolution
Side A sensor (PS2)
Side B sensor (PS3)
Laser
Laser scanner motor