CHAPTER 5 LASER EXPOSURE SYSTEM
5-14
COPYRIGHT © 1999 CANON INC. CANON CLC1120/1130/1150 REV.0 MAR. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
2) Select T-V00, enter ‘255’, and press the
ON key.
3) Select T-V00-ON, and press the OK key
(so as to turn on the laser). Record the
value (offset value) indicated. To stop the
laser output, press the Stop key.
4) Select T-V00, and adjust its value so that
it is as shown:
offset value + (0.15 to 0.20 mV)
5) Likewise, adjust the following according
to their respective values recorded on the
label: T-VFF, P3-V00, P3-VFF-1, P3-
VFF-2, P3-VFF-3, P3-VFF-4.
To stop the laser output, press the Stop
key.
Use the following as a guide to standard
values:
Item
Standard
Laser ON key
T-V00
Offset Value
T-V00-ON
+ (0.15 to 0.20)
T-VFF
Pmax
T-VFF-ON
x 70%
P3-V00
Offset value
P3V00-ON
+ (0.1 to 0.15)
P3-VFF-1
Pmax x 45%
P3-V1-ON
P3-VFF-2
Pmax x 55%
P3-V2-ON
P3-VFF-3
Pmax x 65%
P3-V3-ON
P3-VFF-4
Value on
P3-V4-ON
label x 70%
6) Press the Reset key to end service mode.
7) Turn off the power switch.
8) Detach the laser power checker, and fit the
cover to the slot.
9) Mount the left inside cover.
Summary of Contents for CLC 1120
Page 6: ......
Page 20: ......
Page 22: ......
Page 48: ......
Page 94: ......
Page 96: ......
Page 114: ......
Page 134: ......
Page 136: ......
Page 152: ......
Page 242: ......
Page 346: ......
Page 374: ......
Page 376: ......
Page 412: ......
Page 452: ......
Page 454: ......
Page 517: ......
Page 881: ......
Page 893: ......
Page 895: ......
Page 899: ......