b. Flow of initial setting control using the black toner concentration sensor and its
related detail code (at time of replacement of developer)
(The notation “xx” in detail code indicates the color of the developing assembly; i.e., xx=02: C,
xx=03: Y, xx=04: Bk.)
Initial settings
1. Feeding
developer
2. Stirring
3. Reading
initial
settings
3.1
Idle
rotation
for 30 sec
3.2
Setting
SGAIN-K,
RGAIN-K
3.3
Reading
SGNL-D,
REF-D
3.4
Reading
SGNL-M/
C/Y/K,
REF-M/C/
Y/K
Flow of operation
Feeds developer to the
developing assembly.
(FUNCTION>INSTALL>
SPLY-K)
Stirs the developer inside
the developing assembly.
(FUNCTION>INSTALL>
STIR)
(FUNCTION>INSTALL>
INIT-K)
Stirs the developer inside
the developing assembly.
LED on; uses PS1/2 to
check light; converts light
into voltage to set gain.
RGAIN-K: set to 4 V
(PS1)
SGAIN-K: set to 3 V
(PS2)
LED on; uses PS1/2 to
check light; converts light
into voltage to set the
following:
REF-D (PS1)
SGNL-D (PS2)
As many as 16 patches are
formed on the
photosensitive drum, are
measured by PS1 to set
the following:
REF-M/C/Y/K (PS1)
SGNL-M/C/Y/K (PS2)
Items of detection
The PS2 connector is disconnected.
The PS1 connector is disconnected.
SGAN cannot be set.
RGAIN cannot be set.
The level of variation in one
sample of REF-xx is 35 or higher.
The level of variation in 16
samples of REF-xx is 70 or higher.
The initial value is 777 or lower.
The initial value is 859 or higher.
Detail code
0400
0401
0440
0441
XX15
XX17
XX23
XX33
Summary of Contents for CLC 1120
Page 6: ......
Page 20: ......
Page 22: ......
Page 48: ......
Page 94: ......
Page 96: ......
Page 114: ......
Page 134: ......
Page 136: ......
Page 152: ......
Page 242: ......
Page 346: ......
Page 374: ......
Page 376: ......
Page 412: ......
Page 452: ......
Page 454: ......
Page 517: ......
Page 881: ......
Page 893: ......
Page 895: ......
Page 899: ......