CHAPTER 7 PICK-UP / FEEDING SYSTEM
7-62
COPYRIGHT © 1999 CANON INC. CANON CLC1120/1130/1150 REV.0 MAR. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
7) Remove the two screws [11], and detach
the lower paper guide plate [12].
Figure 7-735
8) Remove the separation roller [13].
Caution:
The separation roller is secured in
position to the shaft with parallel pin.
Take good care not to drop the pin when
removing or mounting it.
Figure 7-736
Reference:
a. Mount the pickup roller [1] so that
the round marking is at the rear.
b. Mount the feed roller [2] so that the
round marking is at the rear.
c. Mount the separation roller [3] so
that the round marking is at the rear.
Figure 7-737
[11]
[12]
[13]
[1]
[2]
[3]