COPYRIGHT © 1999 CANON INC. CANON CLC1120/1130/1150 REV.0 MAR. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
7-63
CHAPTER 7 PICK-UP / FEEDING SYSTEM
3. Left/Right Registration
If left/right registration is wrong when
pickup is from the multifeeder, adjust the
screw [1] to adjust the position of the tray.
Figure 7-738
Figure 7-739
4. Attaching the Timing Belt for the
Multifeeder Assembly
Keep the rack plate [1] of the multifeeder
closed.
Move the slide volume [2] in the direction
of the arrow, and attach the timing belt [3].
Figure 7-740
5. Position of the Multifeeder Pickup
Solenoid
The position of the solenoid need not be
adjusted, but be sure to mount it where it
initial was (as upon shipment from the
factory). To do so, be sure to mark the position
of the solenoid with a scribe before removing
it.
[1]
0
2
4
6
8
10
2.0 1.5mm
[1]
[2]
[3]