CHAPTER 13 TROUBLESHOOTING
13-158
COPYRIGHT © 1999 CANON INC. CANON CLC1120/1130/1150 REV.0 MAR. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
6
Delivery Vertical Path/Duplexing Feeding Assembly
Cause
Delivery paper
deflecting plate
Delivery vertical
path roller 1/2/3
External delivery
sensor
Delivery vertical
path 1 sensor
Delivery vertical
path 2 sensor
Duplexing
feeding drive
assembly
Duplexing
feeding assembly
sensor
Paper guide plate
Action
Check the delivery paper
deflecting plate solenoid
(SL10).
Check the fixing motor
and the duplexing motor
driver assembly; if
normal, replace the
delivery vertical path
clutch (CL19).
Check the sensor lever
and wiring; if normal,
replace the sensor.
Check the duplexing
motor drive assembly.
Check the sensor lever
and wiring; if normal,
replace the sensor.
Check each paper guide
plate and the duplexing
feeding assembly or
foreign matter and
deformation.
Step
1
2
3
4
5
Yes/No
NO
NO
NO
NO
NO
YES
Checks
Is the delivery paper deflecting
plate operating normally?
Is the delivery vertical path roller
operating normally?
Is each sensor (PS31, PS32, PS33)
operating normally?
Is the duplexing feeding assembly
operating normally?
Is the sensor (PS34, PS37) of the
duplexing feeding assembly
operating normally?
Summary of Contents for CLC 1120
Page 6: ......
Page 20: ......
Page 22: ......
Page 48: ......
Page 94: ......
Page 96: ......
Page 114: ......
Page 134: ......
Page 136: ......
Page 152: ......
Page 242: ......
Page 346: ......
Page 374: ......
Page 376: ......
Page 412: ......
Page 452: ......
Page 454: ......
Page 517: ......
Page 881: ......
Page 893: ......
Page 895: ......
Page 899: ......