CHAPTER 13 TROUBLESHOOTING
13-160
COPYRIGHT © 1999 CANON INC. CANON CLC1120/1130/1150 REV.0 MAR. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
Cause
Separation roller
Pressure spring
Action
Replace the separation
roll.
Adjust the position of
the pressure spring.
Replace the pressure
spring.
Step
1
Yes/No
YES
NO
Checks
Is the separation roller deformed or
worn?
B. Feeding Faults
1
Double Feeding
2
Wrinkles
Cause
Cassette pickup
assembly,
Duplexing
assembly
Copy paper
Fixing inlet guide
Nip (fixing)
Fixing upper/
lower roller
Action
Check each pickup
assembly and the
registration roller
assembly.
The copy paper may be
moist. Advise the user
on the correct method of
storing paper.
Advise the user to use
recommended paper.
Check to see if the
cassette heater is
operating normally.
Clean the guide with
solvent.
Adjust the nip.
Try replacing the upper
and lower rollers in
turns.
Step
1
2
3
4
5
Yes/No
YES
YES
YES
NO
YES
NO
YES
Checks
Turn off the power switch while
copy paper is moving through the
pickup vertical path/registration
feeding assembly.
At this time, is the copy paper
wrinkled?
Or, is the copy paper askew?
Try copy paper fresh out of
package. Is the problem corrected?
Try paper of a type recommended
by Canon. Is the problem
corrected?
Is the fixing inlet guide soiled with
toner?
Is the nip (pressure) as indicated?
Summary of Contents for CLC 1120
Page 6: ......
Page 20: ......
Page 22: ......
Page 48: ......
Page 94: ......
Page 96: ......
Page 114: ......
Page 134: ......
Page 136: ......
Page 152: ......
Page 242: ......
Page 346: ......
Page 374: ......
Page 376: ......
Page 412: ......
Page 452: ......
Page 454: ......
Page 517: ......
Page 881: ......
Page 893: ......
Page 895: ......
Page 899: ......