1 Selecting the Site
Select the site of installation with the fol-
lowing considerations in mind; if possible,
pay a visit to the user’s before delivering the
machine.
1. Make sure that the power supply en-
ables exclusive connection to a recep-
tacle rated as follows, and the appropri-
ate terminal of the receptacle is properly
grounded for safety:
Model
Voltage
Amperage Receptacle
1North American 208/240 V*15 A
NEMA 6-20R
2European
230 V
16 A
DIN49440/49441
3UK
230 V
13 A
BS1363
4Australian
230 V
15 A
AS
2. The temperature and humidity require-
ments must be as shown in Figure F03-
100-01. Avoid areas near water faucets,
water boilers, humidifiers, or refrigera-
tors.
F03-100-01
0
5
10
15
20
25
30
˚C
10
20
30
40
50
60
70
80
90
Humidity (%)
25
75
27.5