Chapter 11
11-15
2. Temperature Table (Low temperature: Room temperature < 18 deg C)
First in the morning (during 15 min after start-up): To 899 sec from 'ready'
T-11-14
STBY (15 min after start-up): 900 sec or later from 'ready'
T-11-15
3. Temperature Table (High temperature: Room temperature >/= 27 deg C)
T-11-16
11.2.2.6 Temperature rise at end
1. Temperature rise control at end of IH heater
[1] Step 1
If either the sub-thermistor 1 (TH2) or the sub-thermistor 2 (TH3) detects 215 deg C, the upper limit of power
applied to the IH heater is lowered. (Power at print mode *1 -> 500W)
If both of the sub-thermistor 1 (TH2) and the sub-thermistor 2 (TH3) detect less than 215 deg C, the upper limit
of power applied to the IH heater is returned to original. (500W -> Power at print mode)
[2] Step 2
If either the fixing sub-thermistor 1 (TH2) or the fixing sub-thermistor 2 (TH3) detects 220 deg C, the power
applied to the IH heater becomes 0W.
If both of the fixing sub-thermistor 1 (TH2) and the fixing sub-thermistor 2 (TH3) detect less than 215 deg C,
the system moves to step 1.
Time passed from Start of Printing
0 to 9
10 to 19
20 to 29
30 to 39
40 to 49
50 to
300 to
iR C5180
Plain paper
Fixing belt
210 deg C
205 deg C
200 deg C
195 deg C
190 deg C
190 deg C
190 deg C
Pressure belt
140 deg C
120 deg C
iR C4580/4080
Plain paper
Fixing belt
210 deg C
205 deg C
200 deg C
195 deg C
190 deg C
185 deg C
185 deg C
Pressure belt
OFF
Time passed from Start of Printing
0 to 9
10 to 19
20 to 29
30 to 39
40 to 49
50 to
300 to
iR C5180
Plain paper
Fixing belt
205 deg C
200 deg C
195 deg C
190 deg C
190 deg C
190 deg C
190 deg C
Pressure belt
140 deg C
120 deg C
iR C4580/
4080
Plain paper
Fixing belt
205 deg C
200 deg C
195 deg C
190 deg C
185 deg C
185 deg C
185 deg C
Pressure belt
OFF
Time passed from Start of Printing
0 to 9
10 to 19
20 to 29
30 to 39
40 to 49
50 to
300 to
iR C5180
Plain paper
Fixing belt
205 deg C
200 deg C
195 deg C
190 deg C
185 deg C
185 deg C
185 deg C
Pressure belt 120 deg C
120 deg C
iR C4580/
4080
Plain paper
Fixing belt
205 deg C
200 deg C
195 deg C
190 deg C
185 deg C
180 deg C
180 deg C
Pressure belt OFF
Summary of Contents for Color imageRUNNER C5180 Series
Page 22: ...Chapter 1 INTRODUCTION...
Page 64: ...Chapter 2 INSTALLATION...
Page 110: ...Chapter 3 BASIC OPERATION...
Page 119: ...Chapter 4 BASIC OPERATIONS AS A PRINTER...
Page 129: ...Chapter 5 MAIN CONTROLLER...
Page 138: ...Chapter 5 5 8 F 5 8 CPU HDD ROM access to the program at time of execution...
Page 165: ...Chapter 6 ORIGINAL EXPOSURE SYSTEM...
Page 209: ...Chapter 7 IMAGE PROCESSING SYSTEM...
Page 212: ...Chapter LASER EXPOSURE 8...
Page 239: ...Chapter 9 IMAGE FORMATION...
Page 324: ...Chapter 10 PICKUP FEEDING SYSTEM...
Page 435: ...Chapter 11 FIXING SYSTEM...
Page 460: ...Chapter 11 11 23 F 11 13 SEN3 SEN2 SEN1 SEN2 SEN3 SEN1 SEN2 SEN3 SEN1...
Page 491: ...Chapter 12 EXTERNALS CONTROLS...
Page 498: ...Chapter 12 12 5 F 12 2 FM1 FM7 FM9 FM2 FM13 FM14 FM12 FM11 FM10 FM5 FM3 FM4 FM8 FM6...
Page 512: ...Chapter 12 12 19 2 Remove the check mark from SNMP Status Enabled F 12 10...
Page 553: ...Chapter 13 MEAP...
Page 557: ...Chapter 14 RDS...
Page 569: ...Chapter 15 MAINTENANCE INSPECTION...
Page 578: ...Chapter 16 STANDARDS ADJUSTMENTS...
Page 597: ...Chapter 17 CORRECTING FAULTY IMAGES...
Page 612: ...Chapter 17 17 14 F 17 7 PLG1 ELCB1 SP1 H4 H3 H2 H1 H1 H2 LA1...
Page 617: ...Chapter 18 SELF DIAGNOSIS...
Page 644: ...Chapter 19 SERVICE MODE...
Page 778: ...Chapter 20 UPGRADING...
Page 823: ...Chapter 21 SERVICE TOOLS...
Page 828: ...APPENDIX...
Page 851: ......