O
REMOVE
THE
USER
INTERFACE
BOARD
N
OTE
:
The UIB is attached to a removable bracket. You do not need to remove the
bracket when removing or replacing the UIB.
1.
Shut down and open the ColorPASS (see page 4-4 and page 4-5).
2.
Remove the front panel from the chassis (see page 4-9).
3.
Remove three of the four screws that secure the UIB to the media bracket.
4.
While supporting the UIB, remove the fourth screw.
F
IGURE
4-12
Removing/replacing the user interface board
5.
Disconnect the UIB cable from the connector on the UIB.
Press outward on the connector levers on each side of the connector (see Figure 4-13),
and then detach the connector. Avoid pulling on the cable.
F
IGURE
4-13
Detail of ribbon cable connector
6.
Place the board in an antistatic bag.
Screws
(2 of 4)
UIB
UIB cable
Mounting post on bracket
(1 of 4)
Connector levers
Summary of Contents for COLORPASS-Z6000 PS-NX6000