3-31
CHAPTER 3 MECHANICAL SYSTEM
2) Clean the sensor S1 [3] shown in the
following figure.
[3]
Figure 3-404
2.
Reflecting Face (original sensor)
1) Clean the reflecting face [2] of the original
sensor while keeping the delivery roller [1]
down.
[1]
[2]
Figure 3-405
3.
Registration Sensor (S3)
1) Remove the separation belt unit.
2) Remove the four screws [2], and detach
the separation guide plate [1].
[2]
[1]
[2]
Figure 3-406
3) Remove the two screws [4], and detach the
inside guide plate.
[4]
[3]
[4]
Figure 3-407