Chapter 4
4-33
8) When done, move back the screw [1] to its initial hole, and tighten it fully.
9) Make a copy of the Text Chart, and make sure that the angle is a right angle by comparing
the output and the Test Chart.
4.3.1.8
Angle Guide (angle of opening of 70 deg)
0003-2278
Adjust the angle of opening as follows:
1) Bend over the edge of the rubber cover [1], and mount the angle guide plate [3] in place
using 2 screws [2].
F-4-40
[2]
[1]
[3]
[1]