Chapter 5
5-4
5.2
User Error Code
5.2.1
Alarm Code
0004-5177
The machine flashes the original detection LED at intervals of 240 msec when it identifies
a fault as being an alarm condition.
T-5-3
Code
Fault
Description
xx03
Separation has failed.
The 1st original does not reach the post-separation
sensor.
The 1st original does not reach the registration sensor.
xx11
The number of jam recovery
sheets is greater than the
number of originals.
In jam recovery mode, the tray runs out of originals
before as many as 'the number of recovery sheets - 1'
has been delivered.
xx13
An original has been pulled out. The read sensor is off when the preceding original has
been moved to a point of reading.
xx14
High-speed duplexing
operation fails.
The original is longer than the specified limit.