Chapter 4
4-16
7. Reversing Flapper
1) Open the feeder cover and the open/close guide.
2) Clean the area of the reversing flapper [1] coming into contact with paper using lint-free
paper moistened with alcohol.
F-4-18
4.2.4.3
Sensors
0003-2455
1. Delivery Reversal Sensor, Prism
1) Open the feed cover.
2) Remove the open/close guide.
3) Clean the prism [1] found on the back of the open/close guide using an air blower brush.
F-4-19
4) Remove the delivery guide.
[1]
[1]