Chapter 4
4-26
If you have replaced any of the sensors (i.e., PI7, PI8, PI9), be sure to clean the surface
of the prism before starting to make the adjustments.
Adjustment Procedure
1) Turn on the host machine, and start its service mode.
<Starting Service Mode>
Press the User Mode key; press the 2 an 8 keys at the same time; then, press the user Mode
key once again.
Check to be sure that there is no paper inside the ADF before starting the adjustments.
2) Make the following selections to highlight [SENS-IN]; FEEDER>FUNCTION>SENS-
IN.
3) Press the OK key.
In response, the machine will run an automatic adjustment session, and will indicate
'OK!' if it ends normally.
4) When done, end service mode.
4.3.1.4
Tray Width
0003-3042
To adjust the tray width, go through the steps under either "1. AB-Configuration" or "2.
Inch-Configuration."
1. AB-Configuration
1) Turn on the host machine, and start its service mode.
<Starting Service Mode>
Press the User Mode key; press the 2 and 8 keys at the same time; then, press the User Mode
key once again.
2) Touch the following in sequence on the screen to bring up the Adjustment screen:
FEEDER>FUNCTION>TRY-A4.
3) Move the tray side guide to the index A4/A3.
Summary of Contents for DADF-M1
Page 9: ...Chapter 1 Specifications ...
Page 17: ...Chapter 2 Functions ...
Page 66: ...Chapter 2 2 47 F 2 41 PI8 PI9 PI6 PI2 PI3 PI4 PI5 PI1 PI7 ...
Page 70: ...Chapter 3 Parts Replacement Procedure ...
Page 105: ...Chapter 4 Maintenance ...
Page 114: ...Chapter 4 4 7 F 4 4 F 4 5 23 24 25 21 26 22 29 27 28 1 31 ...
Page 156: ...Chapter 4 4 49 F 4 53 FM1 SL2 SL1 M4 M1 CL1 PCB1 M2 M3 VR1 ...
Page 158: ...Chapter 4 4 51 4 5 3 Original Placement led PCB 0003 5540 F 4 55 J201 1 3 ...
Page 159: ...Chapter 5 Error Code ...
Page 165: ...Appendix ...
Page 171: ......