Chapter 4
4-13
F-4-39
3) Clean the manual feed registration roller [3] with lint-free paper or a cloth
mounted with alcohol.
F-4-40
4) Shift up the DADF, and open the delivery lower guide [4]; then, clean the
manual feed registration roller member [5] with lint-free paper or a cloth
moistened with alcohol.
F-4-41
4.3 Adjustment
4.3.1 Basic Adjustment
4.3.1.1 Basic Adjustments
0011-2714
The basic adjustments of the DADF consist of the following, which must be
performed in sequence:
[1] ADF height adjustment
[2] ADF right angel adjustment
[3] Skew correction
[4] Horizontal adjustment
[5] Original stop position adjustment
4.3.1.2 ADF Height Adjustment
0011-2715
1) Remove the front cover [1].
-Three screws [2] (remove)
-One screw [3] (loosen)
F-4-42
F-4-43
F-4-44
2) Make adjustments by loosening the two fixed screws [5] on the magnet
catch so that the left and right rubber feet are in contact with the base
when the DADF is closed.
F-4-45
3) After the adjustment, tighten the fixing screws on the magnet catch, and
mount the front cover.
4.3.1.3 ADF Right Angle Adjustment
0011-2718
This adjustment is to adjust the right angle made by the copier's scanner and
the DADF's original feed path.
1) Using an A4 or LTR sheet of copy paper, prepare a test chart as shown.
[1]
[2]
[1]
[2]
[1]
[1]
[2]
[3]
[3]
[1]
[2]
[3]
[3]
Summary of Contents for DADF-Q1
Page 1: ...Aug 24 2007 Service Manual Feeder DADF Q1 ...
Page 2: ......
Page 6: ......
Page 11: ...Chapter 1 Specifications ...
Page 12: ......
Page 14: ......
Page 18: ......
Page 19: ...Chapter 2 Functions ...
Page 20: ......
Page 22: ......
Page 75: ...Chapter 3 Parts Replacement Procedure ...
Page 76: ......
Page 107: ...Chapter 4 Maintenance ...
Page 108: ......
Page 149: ...Chapter 5 Error Code ...
Page 150: ......
Page 152: ......
Page 154: ......
Page 155: ...Aug 24 2007 ...
Page 156: ......