6. Back platen roller
1) Dismount the upper unit.
2) Remove two screws A
and detach the
upper reading roller guide
. After removing
four screws B
(two on each side) and the
back side of feed guide plate 1
, slide feed
guide plate 1 to the right to detach it by
unhooking the fit
on the front side.
Screw A
Upper reading roller guide
Screw B
Feed guide plate 1
Fit
Fig. 3-314
3) Remove two E-rings
and two bearings
and detach the back platen roller
.
Additionally, remove two spacers
, the pin
, and the gear
.
Note:
The spacer comes with the bearing.
E-ring
Bearing
Back platen roller
Spacer
Pin
Gear
Fig. 3-315
Precautions during assembly
•
Fix feed guide plate 1 by matching three fits on
the back.