COPYRIGHT © 2003 CANON ELECTRONICS INC. CANON DR-6080/9080C FIRST EDITION OCT. 2003
3 - 39
CHAPTER 3 DISASSEMBLY & REASSEMBLY
2. Pick-up control PCB (80-SUB)
1) Detach the upper delivery cover assembly.
2) Unhook all connectors connected to the
pick-up control PCB, remove two screws
,
and then detach the pick-up control PCB
while removing two stoppers
.
Pick-up control PCB
Screw
Stopper
Fig. 3-503
Precautions during assembly
•
Make sure that every cable is connected and
securely inserted.
•
Do not pull in the cables. Fix them using cable
clamps.
3. Document tray control PCB
(10-SUB)
1) Detach the right cover assembly.
2) Unhook all connectors connected to the
document tray control PCB
and remove
one screw A
and two screws B
(self-tapping)
.
Document tray control PCB
Screw A
Screw B
Fig. 3-504
3) Disconnect two connectors
attached to
the back side of the document tray control
PCB
.
Document tray control PCB
Connector
Fig. 3-505
Summary of Contents for DR-6080
Page 4: ......
Page 22: ......
Page 182: ......
Page 188: ...1003N0 0 1 ...
Page 195: ...COPYRIGHT 2003 CANON ELECTRONICS INC CANON DR 6080 9080C FIRST EDITION OCT 2003 vii ...
Page 236: ......
Page 240: ......
Page 242: ...ix 1003N0 0 0 ...
Page 284: ...38 Chapter 3 Software Closing CapturePerfect 1 Select Exit from the File menu ...
Page 308: ......
Page 352: ...1 Imprinter for DR 6080 9080C Installation Procedure IMS Product Planning Dept ...
Page 355: ...4 3 Remove the left cover 4 screws Remove these screws x4 ...
Page 359: ...8 7 Insert it firmly to the back and fix it with 1 screw M3x6 ...
Page 366: ...15 14 Replace the cable to cable clamp and the document eject cover to the original position ...