8-20
Chapter 8 ISIS/TWAIN Driver Settings
IMPORTANT
If the documents overlap by less than 1.97" (50 mm), or if the
documents cling (such as from static electricity), ultrasonic
detection of double feeds may not word correctly.
Feeding Option
You can select the feeding method for document scanning.
[Standard Feeding]
Load a document and then start scanning with an
application program. Scanning stops when the loaded
document has been scanned.
[Manual Feeding] (Separation Off)
This is linked to the [Separation Off] key on the control
panel. When [Manual Feeding] is selected, the [Separation
Off] key is lit and the Document Feed Tray is raised up.
Start scanning with an application program and feed
documents manually one at a time. The scanner detects a
document and then scans it. Press the stop key to stop
scanning.
Hint
If you press the [Separation Off] key on the control panel, the
feeding option changes to [Manual Feeding].
[Panel-Feeding]
Start scanning with an application program, load a
document, and then press the start key to start the scan
operation.
The scanner enters a waiting state when the document has
been scanned, and then continues scanning when you load
the next document and press the start key. When all of the
documents have been scanned, press the stop key to stop
scanning.
Hint
When using the panel feeding mode to scan documents with
different-size pages, you can adjust the document guide
position after loading a document.
[Automatic Feeding]
Execute scanning with an application. The scanner starts
scanning when it detects a document loaded in the
Document Feed Tray.
The scanner enters a waiting state when the document has
been scanned, and then continues scanning when it detects
the next document. When all of the documents have been
scanned, press the stop key to stop scanning.
[Setting] Button
This button is enabled when [Automatic Feeding] is
selected, and allows you to set the delay time from when a
loaded document is detected until scanning starts.
Batch Separation
Items available for selection depend on the Feeding Option
setting: select batch separation timing (for when to start
scanning) according to the batch separation capabilities
provided by the application program.
[Standard Feeding] feeding option, batch separation is not
available
[Manual Feeding] Feeding Option