E11
⑤
AUX (see pin assignment at right)
A terminal block for external equipment control.
Supported wire gauges: AWG 28–22. Stripped
wire length: 9 to 10 mm.
For details of external device I/O of pins 3–6,
refer to the installation manual.
⑥
RS-422 (see pin assignment at right)
An input for remote control. Connect one end of
an RJ-45 UTP cable here and the other end to
the operation unit.
⑦
HD-SDI (BNC)
Output for HD-SDI signals. Connect to HD video
monitors or relay equipment.
⑧
SYNC (BNC)
Input for external sync signals. Synchronization
with the HD-SDI output signals is possible
⑨
VBS (BNC)
Output for SD composite signals (PAL/NTSC) for
monitor display. Connect to a video monitor.
⑩
AUDIO OUT (RCA pin jack)
Mic audio output. Connect to speakers or relay equipment.
⑪
Mic
Internal waterproof microphone.
⑫
Tally Lamp
Can be lit in red in response to communication commands.
5-1-2. Optional Units
・
Wiper, Motorized ND Filter
(standard equipments on XU-81W)
・
Washer
An wiper and a motorized ND filter can be installed. Additionally, an external washer or less can
be connected. For further information, contact your Canon dealer or your Canon sales repre-
sentative.
For installation, please refer to the separate "Installation Manual".
5-2. Pan-Tilt Head, Camera, and Lens Operation
The XU-81 main unit is controlled from the operation unit.The functions and operating procedures
vary depending on the operation unit that is used.
For further information, please refer to the operation manual of your operation unit.
⑤
AUX (terminal block)
Pin No.
Signal
1
ACC CONT
(open drain)
2
+12V output
(500 mA or lower)
3
AUX OUT(3)
4
AUX OUT(4)
5
GND
6
AUX IN
3, 4: Connectors for external device output
5, 6: Connectors for external device input
⑥
RS-422
(
RJ-45
)
Pin No.
Signal
2
GND
3
RXD+ (IN)
4
TXD- (OUT)
5
TXD+ (OUT)
6
RXD- (IN)
7
GND