8
8
8-17
8-17
Service Mode > TESTMODE > NETWORK > SSSW
Service Mode > TESTMODE > NETWORK > SSSW
●
RELAY-1
TESTMODE>FAX>MODEM>RELAY-1
Sub item
Description
FAX model only
CML
Test ON/OFF of port SW and relay on NCU
Setting value: ON, OFF
Yes
H
Test ON/OFF of port SW and relay on NCU
Setting value: ON, OFF
Yes
■
FACULTY
TESTMODE>FAX>FACULTY
Sub item
Description
FAX model only
G34800TX
Transmit the frequency of 4800bps using G3 signal transmission
function after DC circuit closure.
Yes
DETECT1
Ring detection
Check the status (ON, OFF) of hook and Ci, Fc from i line.
Yes
DETECT2
CNG detection test 1
Execute CNG signal check and FED check.
Detect CNG after CML relay is ON.
Yes
DETECT3
CNG detection test 2
Execute CNG signal check and FED check.
Detect CNG after CML relay is OFF.
Yes
■
PANEL
TESTMODE>FAX>PANEL
Sub item
Description
KEY CHECK START
Key check
[Applicable case]
Check if all keys functions normally after replacement of Control Panel.
LED CHECK START
LED check
[Applicable case]
Check if all LEDs are lit normally after replacement of Control Panel.
LCD CHECK START
LCD check
[Applicable case]
Check if LCD can display without any missing dot after replacement of
Control Pannel.
T-8-49
T-8-50
T-8-51
NETWORK
■
SSSW
NETWORK>SSSW
Sub item
BIT
Description
SW01 ~ SW09
0
Not in use
1
2
3
4
5
6
7
SW10
Network Config
System
0
Not in use
1
2
3 Turn ON(Enable)/ OFF(Disable) for acquisition of host name (Option 12) by
DHCP
Default value: 0
4 Turn ON(Enable)/ OFF(Disable) for registration of host name (Option 81) by
DHCP
Default value: 1
5
Not in use
6
7
SW11 ~ SW50
0
Not in use
1
2
3
4
5
6
7
T-8-52
Summary of Contents for FAXPHONE L190
Page 470: ...5 5 Adjustment Adjustment Mechanical Adjustment ...
Page 480: ...7 7 Error Codes Error Codes Overview Error Codes ...
Page 484: ...8 8 Service Mode Service Mode Overview COPIER FEEDER FAX TESTMODE ...
Page 501: ... Service Tools Solvent Oil List General Circuit Diagram General Timing Chart Appendix ...