COPYRIGHT © 1996 CANON INC. CANON GP215/200 REV.0 JULY 1996 PRINTED IN JAPAN (IMPRIME AU JAPON)
3–192
3. OPERATIONS AND TIMING
6. Input/Output Port 2 of the Feeder
a.
RF Input/Output Ports
CANCEL
+
OK
*2* I/O DISPLAY 06
DF-AD0 : xx
DF-AD1 : xx
DF-AD2 : xx
DF-AD3 : xx
DF-AD4 : xx
DF-AD5 : xx
DF-DA0 : xx
DF-DA1 : xx
–
Address
DF-AD0
DF-AD1
DF-AD2
DF-AD3
DF-AD4
DF-AD5
DF-DA0
DF-DA1
Indication
Original sensor (S1)
Registration sensor (S3)
Original width volume (VR1)
Not used
Not used
Not used
Original tray sensor LED1 ON signal
Registration sensor LED3 ON signal
Signal
DEP1
PDP2
DMPS
Logic
In hexadecimal notation.
In hexadecimal notation.
In hexadecimal notation.
Jack
J5-7
J9-20
J8-8
b.
ADF Input/Output Port
Address
DF-AD0
DF-AD1
DF-AD2
DF-AD3
DF-AD4
DF-AD5
DF-DA0
DF-DA1
Indication
Not used
Not used
Not used
Not used
Not used
Not used
Not used
Not used
Signal
Logic
Jack