2. Automatic Density Adjustment
COPYRIGHT © 1996 CANON INC. CANON GP215/200 REV.0 JULY 1996 PRINTED IN JAPAN (IMPRIME AU JAPON)
5–26
5. INSTALLATION
Work
Execute automatic density adjust-
ment.
• Execute ‘PD’, ‘200PWM’, and
‘600PWM’.
Press the Reset key once to
end service mode.
• ‘$’ will be indicated in the
upper left corner of the
screen.
Holding the feeder or the copy-
board cover at about 45°,
make two A4 copies (solid
black).
Press the* key twice.
Press ‘FUNCTION’ (*4*) on the
screen to highlight; then, press
the OK key.
Press the
key to turn
pages to the PD Density
Automatic Adjustment screen.
Close the front cover halfway,
and press ‘PD PRINT’ on the
screen to highlight; then, press
the Copy Start key.
• The copier will generate a
test pattern. (You will use the
Test Pattern later.)
Remarks
No.
1
CANCEL
+
OK
*4* FUNCTION 04
PD PRINT (START)
WHITE MEASURE (OK)
DENSITY SANPLING (OK)
DATA SET
A=+xxx, B=+xxx, D=+xxx
xx xx xx xx xx xx xx
xx xx xx xx xx xx xx
MULTI 0
>CASSETTE1 A4 1
CASSETTE 2 A4 1
–