COPYRIGHT © 1999 CANON INC.
CANON GP605/605V REV.0 JAN. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
4-25
CHAPTER 4 IMAGE PROCESSING SYSTEM
Figure 4-B403
[6]
[6]
[7]
[6]
[6]
[10]
[10]
[10]
[10]
[10]
[9]
[9]
[12] [11]
[8]
[9]
[9]
Figure 4-B404
5) Remove the four screws [6], and detach
the image processor cover [7].
Caution:
At this time, take care not to damage the
flat cable removed in step 4).
6) Disconnect the seven connectors [9] of the
image processor PCB [8], and remove the
six screws [10]; then, detach the image
processor PCB [8].
Caution:
At this time, take care not to damage the
connector [12] of the image processor
PCB and the original orientation PCB
[11].
2.
After Replacing the Image
Processor PCB
See G. "Electrical Parts" under II. of
Chapter 13.