CHAPTER 5 LASER EXPOSURE SYSTEM
5-4
COPYRIGHT © 1999 CANON INC.
CANON GP605/605V REV.0 JAN. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
B.
Basic Sequence of Operations (laser exposure system)
Figure 5-104 Basic Sequence of Operations
Control panel
power switch ON
Copy Start
key ON
195˚C
Image leading
edge signal
Laser A
Laser B
INTR
PSTBY
LSTR
STBY
Laser B
BD signal
Laser scanner
motor
Wait rotation
Wait activation
Activation for imaging
1 scan
Wait activation
Wait rotation
Detects the laser B.
Activation for potential control
Image leading edge signal in
page memory
When the surface temperature of the fixing roller reaches 195˚C,
full-speed rotation is stated. (for potential control)