COPYRIGHT © 1999 CANON INC.
CANON GP605/605V REV.0 JAN. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
6-7
CHAPTER 6 IMAGE FORMATION SYSTEM
Related Service Mode
COPIER>OPTION>BODY>PO-CNT
(potential control on/off)
0: disable potential control.
1: enable potential control. (default)
COPIER>FUNCTION>DPC>OFST
(potential sensor offset adjustment)
For adjustments, see descriptions on electrical parts in
Chapter 13>II. "Standards and Adjustments."
COPIER>ADJUST>V-CONT>EPOTOFST
(potential sensor offset value input)
COPIER>ADJUST>V-CONT>VL-OFST
(VL target potential offset input)
COPIER>ADJUST>V-CONT>VD-OFST
(VD target potential offset value input)
If you have replaced the image processor PCB or
initialized the RAM on the image processor PCB,
enter the value recorded on the service label.