CHAPTER 6 IMAGE FORMATION SYSTEM
Figure 6-213 Sequence of Control
3.
Density Adjustment during Printing (scanner input)
Table 6-204 Timing of Control
WMUPR
WMUP
STBY
195˚C
200˚C
Potential sensor
Laser
Grid bias
Vg
Pw
VD
VL
Potential determined
Vg
Pw
Vdc
1
9
3
5
7
-20V
Density
Darker
Lighter
x 0.8
x 1.0
x 1.2
x 1.5
The laser power/Vdc is corrected
according to the F setting.
Laser power
correction value
Vdc
correction value
Potential control
sequence started.
F value
COPIER>OPTION>USER>
PM-DENS
(density setting mode on/off during
printing)
1: correct the target value to enable variation of density
during printing. (default)
0: disable the mechanism used to vary the density during
printing.
Related Service Mode
Potential control
COPIER > OPTION > BODY > PM-DENS
Set
F setting updated
Main power switch
OFF/ON
Copy Start key
ON
The laser power/Vdc is used
to suit the F value setting.
Summary of Contents for GP605
Page 3: ......
Page 4: ......
Page 24: ......
Page 56: ......
Page 78: ......
Page 116: ......
Page 124: ......
Page 148: ......
Page 150: ......
Page 168: ......
Page 170: ......
Page 250: ......
Page 252: ......
Page 342: ......
Page 390: ......
Page 392: ......
Page 464: ......
Page 466: ......
Page 512: ......
Page 514: ......
Page 572: ......
Page 574: ......
Page 590: ......
Page 592: ......
Page 854: ......
Page 870: ......
Page 874: ......