Controlling the Output to Suit the Environment (fuzzy control)
The transfer current output is controlled to an optimum level to suit the environment (condi-
tions identified based on the data from the environment sensor).
Figure 6-310 Transfer Current Output Table
T
ransf
er
current (
µ
A
)
-150
-650
Low
humidity
High
humidity
COPIER>OPTION>BODY>FUZZY
(fuzzy control ON/OFF)
0: enable fuzzy control. (default)
1: low humidity mode. (The transfer current is lower
than the standard level.)
2: normal humidity mode.
3: high humidity mode. (The transfer current is higher
than the standard level.)
Selecting '1' through '3' makes the control mechanism
independent of the environment sensor.