CHAPTER 6 IMAGE FORMATION SYSTEM
2.
Removing the Photosensitive
Drum
1) Open the front cover.
2) Slide out the process unit. (See Figures 6-
D701 through -D703.)
3) Remove the three screws [1], and discon-
nect the three connectors [2]; then, detach
the auxiliary plate [3].
4) Remove the two screws [4], and detach
the positioning holder [5].
Figure 6-A701
Figure 6-A702
[1]
[1]
[1]
[3]
[2]
[2]
[2]
[5]
[4]