CHAPTER 6 IMAGE FORMATION SYSTEM
Figure 6-A707
[6]
4) Pull out the flat heater (drum heater) [6]
from inside the drum cylinder.
Points to Note When Mounting
the Flange
There is hardly a gap between the flange
and the inner side of the drum, causing
the flange to get stuck if pushed at an
angle.
When mounting the flange, push it in a
parallel direction to the drum without
applying excessive force.
4.
Mounting the Photosensitive
Drum Unit
Mount the photosensitive drum by revers-
ing the steps used to remove it with the follow-
ing in mind.
Caution:
Be sure to attach the bearing stopper as
soon as you have placed the photosensi-
tive drum on the process unit. (Other-
wise, the photosensitive drum may fall,
damaging its surface.)