CHAPTER 8 FIXING SYSTEM
8-4
COPYRIGHT © 1999 CANON INC.
CANON GP605/605V REV.0 JAN. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
B.
Basic Sequence of Operations (fixing system)
Figure 8-103 Basic Sequence of Operations
Wait indicator
RED
RED
GREEN
Fixing motor
Main heater
Sub heater
SLEEP
WMUP
WMUPR
STBY
INTR
PSTBY PRINT
LSTR
STBY
Main power
switch
ON
Control panel
power switch
ON
195˚C
210˚C
205˚C
200˚C
195˚C
200˚C
Copy Start key
ON
Controlled to 200˚C
Controlled to 200˚C
The temperature drops
because of passage of
paper.
Both main and sub heaters
are turned on to return to
200˚C in a short time.