COPYRIGHT © 1999 CANON INC.
CANON GP605/605V REV.0 JAN. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
8-15
CHAPTER 8 FIXING SYSTEM
1.
Transparency Mode
To prevent wrapping of a transparency around the fixing roller (or it would start to melt be-
cause of the heat from the fixing roller), the surface temperature of the fixing roller is lowered in
transparency mode.
Figure 8-303 Sequence of Operations
Wait indicator
Green
Green
Red
Fixing motor
(M3)
Main heater
(H1)
Sub heater
(H2)
STBY
INTR
LSTR
STBY
Transparency
mode selected
Copy
Start key
ON
195˚C
210˚C
205˚C
200˚C
195˚C
Controlled to
200˚C
Controlled to 200˚C
Controlled to
195˚C
Temperature for transparencies
Idle rotation is continued until
the surface temperature of the
fixing roller drops to
transparency mode
temperature.
Related Service Mode
COPIER>OPTION>BODY>OHP-TEMP
(transparency mode temperature setting)
0: disables transparency mode temperature control.
(normal temperature control only)
1: enables transparency mode temperature control at
"normal control level -10˚C."
2: enables transparency mode temperature control at
"normal control level -15˚C."
3: enables transparency mode temperature control at
"normal control level -20˚C."
Summary of Contents for GP605
Page 3: ......
Page 4: ......
Page 24: ......
Page 56: ......
Page 78: ......
Page 116: ......
Page 124: ......
Page 148: ......
Page 150: ......
Page 168: ......
Page 170: ......
Page 250: ......
Page 252: ......
Page 342: ......
Page 390: ......
Page 392: ......
Page 464: ......
Page 466: ......
Page 512: ......
Page 514: ......
Page 572: ......
Page 574: ......
Page 590: ......
Page 592: ......
Page 854: ......
Page 870: ......
Page 874: ......