COPYRIGHT © 1999 CANON INC.
CANON GP605/605V REV.0 JAN. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
8-17
CHAPTER 8 FIXING SYSTEM
3.
Power Save Mode
A press on the Save Power key on the control panel will lower the control temperature used
during STBY to reduce power consumption.
Figure 8-304 Sequence of Operations
Main heater
(H1)
Sub heater
(H2)
Saving by 10%
Saving by 25%
Saving by 50%
200˚C
195˚C
180˚C
155˚C
110˚C
STBY
SLEEP
STBY
WMUP
Power save mode
selected in user mode
Save Power
key
ON
Save Power
key
OFF
195˚C
200˚C
Controlled to 200˚C
WMUPR omitted
The Save Power key is
turned off, returning to
normal temperature.
Controlled to 200˚C
Temperature
control according
to saving rate