Figure 8-308 Sequence of Operations (error detection)
Fixing motor
(M3)
Main heater
(H1)
Sub heater
(H2)
150˚C
100˚C
2.5 min
3 sec
SLEEP
WMUP
Main power
switch ON
Control panel
power switch
ON
Main power
switch OFF
[1]E002
[1] The main thermistor does not detect
100˚C within 3 min after it has detected 70˚C.
[2] The main thermistor does not detect
100˚C within 3 min after it has detected 100˚C.
70˚C