CHAPTER 13 TROUBLESHOOTING
13-48
COPYRIGHT © 1999 CANON INC.
CANON GP605/605V REV.0 JAN. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
Potential sensor support plate
Screws
Connectors
Potential sensor support plate
4) Remove the two screws, and replace the potential sensor support plate.
Figure 13-G204
5) Put back the developing assembly and the process unit.
6) Connect the connector of the potential sensor.
Figure 13-G205