E602-0006--
Firmware error
Detection Description
Loading of Subbootable ends in failure.
Remedy
1. Turn OFF and then ON the power.
2. Replace the Main Controller PCB.
E602-0007--
Firmware error
Detection Description
Damage on the internal file
Remedy
1. Turn OFF and then ON the power.
2. Replace the Main Controller PCB.
E602-0008--
The memory area in the Main Controller is depleted
Detection Description
Remaining memory area in the Main Controller is small.
Remedy
* Turning OFF and then ON the main power stops the error code to be displayed, but the continuous
use causes the memory area in the Main Controller PCB to be completely used up or causes
symptoms such as machine freeze.
1. Replace the Main Controller PCB.
E602-0009--
MEAP cannot be started.
Detection Description
MEAP cannot be started due to an error caused by invalid power down.
Remedy
1. Select Function.gr > MEAP > MEAP FUNCTION = ON, and turn OFF and then ON the main
power.
* Since the installed MEAP application and its management information are all cleared after reboot,
MEAP needs to be reinstalled.
E602-1102--
File system could not be initialized normally. (MEAP-related)
Detection Description
File system could not be initialized normally.
Remedy
1. Turning OFF and then ON the main power executes auto recovery. Since E616-0001 may be
displayed in some cases, execute the remedy for E616-0001.
* When this error occurs, the firmware downloaded by the CDS Updater will be lost.
E602-1112--
Device access error (MEAP-related)
Detection Description
Device access error
Remedy
1. Turning OFF and then ON the main power executes auto recovery. Since E616-0001 may be
displayed in some cases, execute the remedy for E616-0001.
* When this error occurs, the firmware downloaded by the CDS Updater will be lost.
E602-1113--
Device access error (MEAP-related)
Detection Description
Device access error
Remedy
1. Turning OFF and then ON the main power executes auto recovery. Since E616-0001 may be
displayed in some cases, execute the remedy for E616-0001.
* When this error occurs, the firmware downloaded by the CDS Updater will be lost.
E602-1302--
File system could not be initialized normally.
Detection Description
File system could not be initialized normally.
Remedy
1. Turning OFF and then ON the main power executes auto recovery.
* When this error occurs, the firmware downloaded by the CDS Updater will be lost.
E602-1312--
Device access error
Detection Description
Device access error
Remedy
1. Turning OFF and then ON the main power executes auto recovery.
* When this error occurs, the firmware downloaded by the CDS Updater will be lost.
E602-1313--
Device access error
Detection Description
Device access error
Remedy
1. Turning OFF and then ON the main power executes auto recovery.
* When this error occurs, the firmware downloaded by the CDS Updater will be lost.
8. Error/Jam/Alarm
201
Summary of Contents for imageCLASS LBP325dn
Page 11: ...Safety Precautions Laser 2 Power Supply Lithium Battery 3 Toner Safety 3 Notes on works 4...
Page 15: ...Product Overview 1 Product Lineup 6 Features 7 Specifications 8 Parts Name 11...
Page 141: ...5 Remove the Right Cover Unit 5 Parts Replacement and Cleaning 131...
Page 187: ...Adjustment 6 Actions at Parts Replacement 178...
Page 204: ...Error Jam Alarm 8 Overview 195 Error Code 197 Jam code 205 Alarm Code 208...
Page 219: ...Service Mode 9 Overview 210 Service Mode 214...
Page 243: ...Installation 10 Installation of the host machine 234...