Chapter 10
10-3
10.1.4 Drum motor failure detection
0020-2655
imageCLASS MF9170c / imageCLASS MF9150c / imageCLASS MF8450c
The DC controller determines that a failure occurred in the drum motors (M6 to 9) in any of the following cases. The machine stops operation and displays "E012
(Drum motor error)" on the control panel.
- Drum motor start-up failure
The interval of the drum motor speed signal is not settled at the specified interval even when 2.5 seconds elapse after start-up of the drum motor.
- Drum motor rotation failure
After the drum motor speed signal is settled at the specified interval, it becomes out of the specified interval for more than 2 seconds continuously.
10.1.5 ETB motor failure detection
0020-2656
imageCLASS MF9170c / imageCLASS MF9150c / imageCLASS MF8450c
The DC controller determines that a failure occurred in the ETB motor (M5) in any of the following cases. The machine stops operation and displays "E012 (ETB
motor failure)" on the control panel.
- ETB motor start-up failure
The interval of the ETB motor speed signal is not settled at the specified interval even when 3.5 seconds elapse after start-up of the ETB motor.
- ETB motor rotation failure
After the ETB motor speed signal is settled at the specified interval, it becomes out of the specified interval for more than 2 seconds continuously.
10.1.6 Fixing motor failure detection
0020-2657
imageCLASS MF9170c / imageCLASS MF9150c / imageCLASS MF8450c
The DC controller determines that a failure occurred in the fixing motor (M1) in any of the following cases. The machine stops operation and displays "E014 (Fixing
motor failure)" on the control panel.
- Fixing motor start-up failure
The interval of the fixing motor speed signal is not settled at the specified interval even when 2.5 seconds elapse after start-up of the fixing motor.
- Fixing motor rotation failure
After the fixing motor speed signal is settled at the specified interval, it becomes out of the specified interval for more than 2 seconds continuously.
10.1.7 Main Unit Fan Failure Detection
0020-2658
imageCLASS MF9170c / imageCLASS MF9150c / imageCLASS MF8450c
The DC controller determines that a failure occurred in the main unit fan (FM1) when receiving the main unit fan lock signal for more than 10 times consecutively.
The machine stops operation and displays "E804 (Main unit fan failure)" on the control panel.
10.1.8 Duplex Fan Failure Detection
0020-2659
imageCLASS MF9170c / imageCLASS MF9150c / imageCLASS MF8450c
The DC controller determines that a failure occurred in the duplex fan (FM2) when receiving the duplex fan lock signal for more than 10 times consecutively. The
machine stops operation and displays "E805 (Duplex fan failure)" on the control panel.
Summary of Contents for imageCLASS MF9170c
Page 16: ...Chapter 1 Introduction ...
Page 55: ...Chapter 2 Basic Operation ...
Page 61: ...Chapter 3 Main Controller ...
Page 75: ...Chapter 4 Original Exposure System ...
Page 88: ...Chapter 5 Original Feeding System ...
Page 105: ...Chapter 6 Laser Exposure ...
Page 113: ...Chapter 7 Image Formation ...
Page 150: ...Chapter 8 Pickup and Feed System ...
Page 184: ...Chapter 9 Fixing System ...
Page 200: ...Chapter 10 External and Controls ...
Page 230: ...Chapter 11 Maintenance and Inspection ...
Page 233: ...Chapter 12 Measurement and Adjustments ...
Page 237: ...Chapter 13 Correcting Faulty Images ...
Page 260: ...Chapter 14 Error Code ...
Page 272: ...Chapter 15 Special Management Mode ...
Page 280: ...Chapter 16 Service Mode ...
Page 322: ...Chapter 17 Upgrading ...
Page 327: ...Chapter 17 17 4 3 Click Next F 17 4 4 Select a USB connected device and click Next F 17 5 ...
Page 328: ...Chapter 17 17 5 5 Click Start F 17 6 6 Click Yes F 17 7 Download will be started F 17 8 ...
Page 330: ...Chapter 18 Service Tools ...
Page 334: ...Appendix ...
Page 349: ......