3 - 36
COPYRIGHT © 2003 CANON ELECTRONICS INC. CANON DR-6080/9080C FIRST EDITION OCT. 2003
CHAPTER 3 DISASSEMBLY & REASSEMBLY
2. Back reading unit
1) Detach the platen unit and the lower reading
roller. Refer to the "Lower reading roller"
section.
2) Unhook the cable clamp
and pull the back
reading unit
out toward the front.
Cable clamp
Back reading unit
Fig. 3-403
3) Unhook three connectors
and detach the
back reading unit
.
Fig. 3-404
Connector
Back reading unit
Precautions during assembly
•
Be careful not to pull in the connected cable
assembly.
•
Since the leaf spring is attached to the rear side
of the back reading unit, push it as far as it will
go while pressing it against the bottom.
•
Clean the reading glass.