4 - 6
COPYRIGHT © 2003 CANON ELECTRONICS INC. CANON DR-6080/9080C FIRST EDITION OCT. 2003
CHAPTER 4 INSTALLATION & MAINTENANCE
No. Procedure
Inspection/Remarks
5
Secure the IP drain unit using screws (BH,
M3x6).
6
Dismount the upper delivery cover assembly.
Note:
Refer to “CHAPTER 3: DISASSEMBLY
& REASSEMBLY."
7
Insert the IP shaft into the IP carriage.
Note:
Be careful to insert the IP shaft in the
correct direction. As illustrated in the
right figure, insert the IP shaft into the
IP carriage so that the short convex tip
of the shaft is to the left and the longer
tip is to the right.
Long
Short
8
Insert the longer convex tip of the IP shaft into
the hole inside the right side of the main body.