COPYRIGHT © 2003 CANON ELECTRONICS INC. CANON DR-6080/9080C FIRST EDITION OCT. 2003
5 - 27
CHAPTER 5 TROUBLESHOOTING
VIII. AFTER REPLACING PARTS
Some of the parts used in this machine
require adjustments and settings after being
replaced or disassembled/reassembled.
Check document feed and images after the
replacement or disassembly/reassembly of the
parts.
1. Main CPU PCB
1) When the SCSI is used, the SCSI ID and
terminator must be set.
2) Perform the following items using the service
mode.
•
Registration adjustment
•
Setting of total counter
3) When custom gamma data is to be used,
enter the data.
2. Pick-up sensor
When the pick-up sensor is not properly
installed, the document tray motion and feeding
are not performed correctly.
Therefore, the adjustment of the pick-up
sensor position is required not only after
replacing parts, but also when a malfunction
occurs after changing the position of the pick-up
sensor.
The position is correct if the pick-up sensor
turns ON when the document tray reaches the
top with plain copy paper set on the document
tray.
•
Checking the operation
1) Select “Dcon Check” in the service mode
and keep the operating condition of the
pick-up sensor visible.
If the pick-up sensor is illuminating when the
document tray is not raised up, position
adjustment is required.
2) Press the “Count Only” key on the operation
panel of the main body to activate the Count
Only mode.
3) Set plain copy paper on the document tray.
4) Press the “Start" key to feed the document.
5) If the pick-up sensor turns ON and the paper
is correctly fed when the document tray
reaches the top, everything is OK. Otherwise,
position adjustment is required.
Summary of Contents for ImageFormula DR-9080C
Page 4: ......
Page 22: ......
Page 182: ......
Page 188: ...1003N0 0 1...
Page 195: ...COPYRIGHT 2003 CANON ELECTRONICS INC CANON DR 6080 9080C FIRST EDITION OCT 2003 vii...
Page 236: ......
Page 240: ......
Page 242: ...ix 1003N0 0 0...
Page 284: ...38 Chapter 3 Software Closing CapturePerfect 1 Select Exit from the File menu...
Page 308: ......
Page 352: ...1 Imprinter for DR 6080 9080C Installation Procedure IMS Product Planning Dept...
Page 355: ...4 3 Remove the left cover 4 screws Remove these screws x4...
Page 359: ...8 7 Insert it firmly to the back and fix it with 1 screw M3x6...
Page 366: ...15 14 Replace the cable to cable clamp and the document eject cover to the original position...