2 - 42
COPYRIGHT © 2003 CANON ELECTRONICS INC. CANON DR-6080/9080C REV.0 SEPT. 2003
CHAPTER 2 FUNCTIONS & OPERATION
2. Protection
Function
The DC power supply PCB is a switching
regulator type.
If the load is shorted and there is an
over-current situation, the protection function is
activated and the output is stopped.
Once the output stops, it can be
automatically restored by turning the power
switch off, eliminating the cause of the short
circuit, discharging the capacitor (for about 10
minutes) and then turning on the power switch.
A fuse is used for protection on each PCB.
If an excessive current flows into the DC/DC
converter, the fuse blows and stops the power
supply to the PCB.
A fuse is also used for protection of the
main motor. If an excessive current flows in the
+ 24 VDC supplied to the main motor, the fuse
blows and stops the power supply to the main
motor.
3. Power Saving Mode
This machine will shift into the power saving
mode if no key or pick-up operation takes place
for 10 minutes or more, when the power is on. In
the power saving mode, power consumption is
minimized and the electrical circuits enter the
“sleep” state. The CPUs, however, do not shift
into power saving mode.
The machine shifts back to the standby
mode when any communication is carried out on
the computer side or when any key on the
operation panel is pressed.
Setting the power saving mode is carried out
in the user mode.
Summary of Contents for ImageFormula DR-9080C
Page 4: ......
Page 22: ......
Page 182: ......
Page 188: ...1003N0 0 1...
Page 195: ...COPYRIGHT 2003 CANON ELECTRONICS INC CANON DR 6080 9080C FIRST EDITION OCT 2003 vii...
Page 236: ......
Page 240: ......
Page 242: ...ix 1003N0 0 0...
Page 284: ...38 Chapter 3 Software Closing CapturePerfect 1 Select Exit from the File menu...
Page 308: ......
Page 352: ...1 Imprinter for DR 6080 9080C Installation Procedure IMS Product Planning Dept...
Page 355: ...4 3 Remove the left cover 4 screws Remove these screws x4...
Page 359: ...8 7 Insert it firmly to the back and fix it with 1 screw M3x6...
Page 366: ...15 14 Replace the cable to cable clamp and the document eject cover to the original position...