5-16
COPYRIGHT © CANON ELECTRONICS INC. 2012
CANON P-208 FIRST EDITION
CHAPTER 5 TROUBLESHOOTING
4) The adjustment proceeds automatically
while the progress screens are displayed.
Figure 5-225
5) The sheet is fed. After the adjustment is
complete, the progress screen disappears
and the screen returns to the service
screen.
Note:
If the error screen appears, select
[OK] and terminate the service mode.
Then restart the service tool, verify the
adjustment sheet and the operation
procedure and execute the adjustment
again.
The example of error screen is shown
below.
Figure 5-226
2. Registration (Manual)
Normally, registration adjustment is
performed in automatic mode, but this
manual adjustment is used to fine adjust
results of automatic adjustment. Note that it
does not reduce variations in the registration
position.
Adjustment sheet
Use the same sheet as the scale pa-
rameter adjustment sheet. For details,
refer to the “Registration (Auto)” section.
Operation Procedure
1) Perform the operation procedure in the
“Registration (Auto)” section.
2) The value adjusted at the Registration
(Auto) is displayed in the data box for the
leading edge.
Figure 5-227
3) When the [Edit] button on the information
screen is selected, the value is displayed
validly and can be modified.