3-12
COPYRIGHT © CANON ELECTRONICS INC. 2011
CANON P-215 FIRST EDITION
CHAPTER 3 DISASSEMBLY & ASSEMBLY
5. Reading unit [lower]
1) Remove the bottom cover.
2) Remove the FFC
{
1
. While holding the
reading unit on the rear side, remove 4
pairs of the fitting parts
{
2
, and then re-
move the reading unit.
Figure 3-309
Notes on assembling
After assembling, clean the front surface
of the reading glass.
6. Reading Cover [lower]
Note:
This part includes the reading glass and
the white reference sheet. Disassem-
bling this part may cause the inside of
the reading unit to get dusty. Do not
disassemble it unless necessary.
When disassembling, be careful with
dusts and do not touch the inner sur-
face of the glass or the surface of the
lens array.
1) Remove the reading unit [lower].
2) Clean the out side including the glass
surface to prevent dust from entering the
reading unit.
3) While removing 9 pairs of the fitting parts
{
1
in order from the end side, remove the
reading unit
{
2
.
Note:
If the reading cover is reused, be
careful not to damage the hooks when
unhooking the fitting parts. The CIS unit
is removed when the reading cover is
removed.
Figure 3-310