Service Mode > COPIER > ADJUST (Adjustment Mode) > V-CONT
Service Mode > COPIER > ADJUST (Adjustment Mode) > V-CONT
■
V-CONT
COPIER> ADJUST> V-CONT
EPOTOFST
Manual entry of potential sensor offset
Lv.1 Details
To set the offset auto adjustment value of potential sensor manually.
As the value is changed by 1, offset value is increased/decreased by
1 V.
+: potential is identified as lower than the detected potential
-: potential is identified as higher than the detected potential
Use case
To restore the value to the factory adjustment when an error is
displayed (when the value out of specified range is set due to
potential sensor cut wire/connection failure/installation failure) on
OFST (auto offset adjustment) at the replacement of potential sensor.
1) To stop the error, set 0 (V) at EPOTOFST.
2) Check around the potential sensor.
If there is an issue, address it and if not, go to the step 3).
3) Enter the value of service label.
4) If fogging etc. occurs, increase the value by 10 V increment.
Adj/set/operate method Enter the setting value and press OK key.
Caution
Do not use this at normal service.
Display/adj/set range
-30 to 30
Unit
1 V
Default value
0
Related service mode
COPIER> FUNCTION> DPC> OFST
VCONT-N
Adj of potntial con dev contrst: qultyPP
Lv.2 Details
To make a fine adjustment of developing contrast target potential that
is used at the potential control with D-max control OFF for quality
paper group only (display/adjustment).
Once D-max control is OFF, density is controlled only by the
environment table information. This can adjust the developing
contrast target potential manually to adjust the density.
As the greater value is set, the density gets high (as the value is
increased by 1, potential is increased by 1 V).
Use case
When D-max control is disabled for some reason.
Adj/set/operate method 1) Check that D-max control is OFF.
2) Enter the setting value and press OK key.
3) Execute the potential control manually.
4) Check the density of solid area in 17 gradations.
Display/adj/set range
-150 to 150
Unit
1 V
Appropriate target value -50 to 50
Default value
0
Related service mode
COPIER> FUNCTION> MISC-P> DMAX-N, EPC
Supplement/memo
Quality paper group: high-quality paper/recycle paper/texture paper/
labels/post cards/cotton
COPIER> ADJUST> V-CONT
VCONT-S
Adj of potntial con dev contrast: coatPP
Lv.2 Details
To make a fine adjustment of developing contrast target potential that
is used at the potential control with D-max control OFF for coated
paper group only (display/adjustment).
Once D-max control is OFF, density is controlled only by the
environment table information. This can adjust the developing
contrast target potential manually to adjust the density.
As the greater value is set, the density gets high (as the value is
increased by 1, potential is increased by 1 V).
Use case
When D-max control is disabled for some reason.
Adj/set/operate method 1) Check that D-max control is OFF.
2) Enter the setting value and press OK key.
3) Execute the potential control manually.
4) Check the density of solid area in 17 gradations.
Display/adj/set range
-150 to 150
Unit
1 V
Appropriate target value -50 to 50
Default value
0
Related service mode
COPIER> FUNCTION> MISC-P> DMAX-S, EPC
Supplement/memo
Coated paper group: 1-sided coat/2-sided coat/vellum/films
VCONT-T
Adj of potntial con dev contrast: thinPP
Lv.2 Details
To make a fine adjustment of developing contrast target potential that
is used at the potential control with D-max control OFF for thin paper
only (display/adjustment).
Once D-max control is OFF, density is controlled only by the
environment table information. This can adjust the developing
contrast target potential manually to adjust the density.
As the greater value is set, the density gets high (as the value is
increased by 1, potential is increased by 1 V).
Use case
When D-max control is disabled for some reason.
Adj/set/operate method 1) Check that D-max control is OFF.
2) Enter the setting value and press OK key.
3) Execute the potential control manually.
4) Check the density of solid area in 17 gradations.
Display/adj/set range
-150 to 150
Unit
1 V
Appropriate target value -50 to 50
Default value
0
Related service mode
COPIER> FUNCTION> MISC-P> DMAX-N, EPC
Supplement/memo
Thin paper: less than 52 to 64 g/m2
Summary of Contents for imagePRESS 1110
Page 242: ...3 3 Periodical Service Periodical Service Periodical service item ...
Page 655: ...5 5 Adjustment Adjustment Overview When replacing parts Major adjustment ...
Page 944: ...8 8 Service Mode Service Mode Overview COPIER FEEDER SORTER BOARD Situation Mode ...
Page 1555: ... Service Tools General Circuit Diagram General Timing Chart Operator Maintenance Appendix ...