Service Mode > COPIER > ADJUST (Adjustment Mode) > FEED-ADJ
Service Mode > COPIER > ADJUST (Adjustment Mode) > FEED-ADJ
COPIER> ADJUST> FEED-ADJ
REG-CST8
Storage side regst adj dspl:Pikup deck8
Lv.1 Details
Display the side registration misalignment position amount of the
storage of the second secondary POD upper deck.
As an indicator when side registration the storage is adjusted.
Use case
When adjusting the side registration of the storage in case that the
correction is not enough at the active registration.
Adj/set/operate method 1) Report the side registration correction amount of each pickup
cassette at the last feed.
2) Display the 1) value on the control panel (rear: +, front: -, unit:
mm)
3) Adjust the side registration position of pickup cassette according
to the displayed value.
If the value is within the adjustment range of active registration (-1
to 1 mm), adjustment is not necessary.
Caution
• After the side registration adjustment of storage, feed the paper
and check the result.
• Do not move the storage that is adjusted for transparency other
than user’s request.
Display/adjust/set range -10 to 10
Unit
1 mm
Appropriate target value -6 to 6
Default value
0
Supplement/memo
On [side registration shift amount offset] that is the fixing assembly
paper edge measure, the value is displayed regardless of the side
registration correction amount.
COPIER> ADJUST> FEED-ADJ
REG-CST9
Storage side regst adj dspl:Pikup deck9
Lv.1 Details
Display the side registration misalignment position amount of the
storage of the second secondary POD middle deck.
As an indicator when side registration the storage is adjusted.
Use case
When adjusting the side registration of the storage in case that the
correction is not enough at the active registration.
Adj/set/operate method 1) Report the side registration correction amount of each pickup
cassette at the last feed.
2) Display the 1) value on the control panel (rear: +, front: -, unit:
mm)
3) Adjust the side registration position of pickup cassette according
to the displayed value.
If the value is within the adjustment range of active registration (-1
to 1 mm), adjustment is not necessary.
Caution
• After the side registration adjustment of storage, feed the paper
and check the result.
• Do not move the storage that is adjusted for transparency other
than user’s request.
Display/adjust/set range -10 to 10
Unit
1 mm
Appropriate target value -6 to 6
Default value
0
Supplement/memo
On [side registration shift amount offset] that is the fixing assembly
paper edge measure, the value is displayed regardless of the side
registration correction amount.
Summary of Contents for imagePRESS 1110
Page 242: ...3 3 Periodical Service Periodical Service Periodical service item ...
Page 655: ...5 5 Adjustment Adjustment Overview When replacing parts Major adjustment ...
Page 944: ...8 8 Service Mode Service Mode Overview COPIER FEEDER SORTER BOARD Situation Mode ...
Page 1555: ... Service Tools General Circuit Diagram General Timing Chart Operator Maintenance Appendix ...