8
8
8-244
8-244
Service Mode > COPIER > OPTION (Mechanical specifications Setting Mode) > IMG-FIX
Service Mode > COPIER > OPTION (Mechanical specifications Setting Mode) > IMG-FIX
COPIER > OPTION > IMG-FIX
TEMP-01
Adj of fixing temp (host machine deck)
Lv.2 Details
Adjusting fixing temperature.
- Plain paper 1 (up to 79 g/m2)/ plain paper 2 (80 to 105 g/m2)
To reduce fixing temperature, reduce the fixing temperature and
the temperature of external heat 1/external heat 2 following the
ratio of 1: 2 (if the fixing temperature is -1 deg C, set external
heat 1/external heat 2 temperature to -2 deg C). To increase
temperature, increase only the fixing temperature while keeping
external heat 1/external heat 2 temperature to 230 deg C.
- Any paper other than plain paper 1 (up to 79 g/m2)/ plain paper 2
(80 to 105 g/m2)
Increase/reduce only the fixing temperature while keeping external
heat 1/ external heat 2 temperature to 230 deg C.
Perform this setting separately with each deck.
Use case
In the case of trouble
Adj/set/operate method Enter the setting value, and then press OK key.
Display/adj/set range
-10 to 3
Unit
1 deg C
Default value
0
Supplement/memo
Increase the range to reduce the temperature because the
fixing roller can be soiled with ink melt with preprint paper (plain
paper reduces the external heat temperature because the
fixing temperature will not be reduced if just adjusting the fixing
temperature).
COPIER > OPTION > IMG-FIX
TEMP-02
Adj of fixing temp (POD upper deck)
Lv.2 Details
Adjusting fixing temperature.
- Plain paper 1 (up to 79 g/m2)/ plain paper 2 (80 to 105 g/m2)
To reduce fixing temperature, reduce the fixing temperature and
the temperature of external heat 1/external heat 2 following the
ratio of 1:2 (if the fixing temperature is -1 deg C, set external
heat 1/external heat 2 temperature to -2 deg C). To increase
temperature, increase only the fixing temperature while keeping
external heat 1/external heat 2 temperature to 230 deg C.
- Any paper other than plain paper 1 (up to 79 g/m2)/ plain paper 2
(80 to 105 g/m2)
Increase/reduce only the fixing temperature while keeping external
heat 1/ external heat 2 temperature to 230 deg C.
Perform this setting separately with each deck.
Use case
In the case of trouble
Adj/set/operate method Enter the setting value, and then press OK key.
Display/adj/set range
-10 to 3
Unit
1 deg C
Default value
0
Supplement/memo
Increase the range to reduce the temperature because the
fixing roller can be soiled with ink melt with preprint paper (plain
paper reduces the external heat temperature because the
fixing temperature will not be reduced if just adjusting the fixing
temperature).
Summary of Contents for imagePRESS 1110
Page 242: ...3 3 Periodical Service Periodical Service Periodical service item ...
Page 655: ...5 5 Adjustment Adjustment Overview When replacing parts Major adjustment ...
Page 944: ...8 8 Service Mode Service Mode Overview COPIER FEEDER SORTER BOARD Situation Mode ...
Page 1555: ... Service Tools General Circuit Diagram General Timing Chart Operator Maintenance Appendix ...