8
8
8-364
8-364
Service Mode > COPIER > COUNTER > DRBL-2
Service Mode > COPIER > COUNTER > DRBL-2
COPIER> COUNTER> DRBL-2
SUB-TQLM
Sub guide PPhold torque limitr cntr:F-AG
Lv.1 Details
1st line: total counter value from the previous replacement
2nd line: estimated life
Use case
When checking the consumption level of parts or replacing the parts.
Adj/set/operate method To clear the counter value: Select the item and press the Clear key.
To change the estimated life: Select the item, enter the value and
press OK key.
Caution
Clear the counter value after replacement.
Display/adj/set range
0 to 99999999
Unit
Number of sheets
Default value
0
TRY-TQLM
Upr tray torque limittr prts cntr:Fin-AG
Lv.1 Details
1st line: total counter value from the previous replacement
2nd line: estimated life
Use case
When checking the consumption level of parts or replacing the parts.
Adj/set/operate method To clear the counter value: Select the item and press the Clear key.
To change the estimated life: Select the item, enter the value and
press OK key.
Caution
Clear the counter value after replacement.
Display/adj/set range
0 to 99999999
Unit
Number of sheets
Default value
0
TR2-TQLM
Lowr tray turque limitr prts cntr:Fin-AG
Lv.1 Details
1st line: total counter value from the previous replacement
2nd line: estimated life
Use case
When checking the consumption level of parts or replacing the parts.
Adj/set/operate method To clear the counter value: Select the item and press the Clear key.
To change the estimated life: Select the item, enter the value and
press OK key.
Caution
Clear the counter value after replacement.
Display/adj/set range
0 to 99999999
Unit
Number of sheets
Default value
0
TRY-CL1
Upr tray oneway clutch prts cuntr:Fin-AG
Lv.1 Details
1st line: total counter value from the previous replacement
2nd line: estimated life
Use case
When checking the consumption level of parts or replacing the parts.
Adj/set/operate method To clear the counter value: Select the item and press the Clear key.
To change the estimated life: Select the item, enter the value and
press OK key.
Caution
Clear the counter value after replacement.
Display/adj/set range
0 to 99999999
Unit
Number of sheets
Default value
0
COPIER> COUNTER> DRBL-2
TRY-CL2
Low tray oneway clutch prts cuntr:Fin-AG
Lv.1 Details
1st line: total counter value from the previous replacement
2nd line: estimated life
Use case
When checking the consumption level of parts or replacing the parts.
Adj/set/operate method To clear the counter value: Select the item and press the Clear key.
To change the estimated life: Select the item, enter the value and
press OK key.
Caution
Clear the counter value after replacement.
Display/adj/set range
0 to 99999999
Unit
Number of sheets
Default value
0
SWG-RB
Swing lever rubber parts counter:Fin-AG
Lv.1 Details
1st line: total counter value from the previous replacement
2nd line: estimated life
Use case
When checking the consumption level of parts or replacing the parts.
Adj/set/operate method To clear the counter value: Select the item and press the Clear key.
To change the estimated life: Select the item, enter the value and
press OK key.
Caution
Clear the counter value after replacement.
Display/adj/set range
0 to 99999999
Unit
Number of sheets
Default value
0
TRM-STC
Trimmer static elmntr prts countr:trimmr
Lv.1 Details
1st line: total counter value from the previous replacement
2nd line: estimated life
Use case
When checking the consumption level of parts or replacing the parts.
Adj/set/operate method To clear the counter value: Select the item and press the Clear key.
To change the estimated life: Select the item, enter the value and
press OK key.
Caution
Clear the counter value after replacement.
Display/adj/set range
0 to 99999999
Unit
Number of sheets
Default value
0
TRM-GD
Trimmer upr guide plate prts cntr:trimmr
Lv.1 Details
1st line: total counter value from the previous replacement
2nd line: estimated life
Use case
When checking the consumption level of parts or replacing the parts.
Adj/set/operate method To clear the counter value: Select the item and press the Clear key.
To change the estimated life: Select the item, enter the value and
press OK key.
Caution
Clear the counter value after replacement.
Display/adj/set range
0 to 99999999
Unit
Number of sheets
Default value
0
Summary of Contents for imagePRESS 1110
Page 242: ...3 3 Periodical Service Periodical Service Periodical service item ...
Page 655: ...5 5 Adjustment Adjustment Overview When replacing parts Major adjustment ...
Page 944: ...8 8 Service Mode Service Mode Overview COPIER FEEDER SORTER BOARD Situation Mode ...
Page 1555: ... Service Tools General Circuit Diagram General Timing Chart Operator Maintenance Appendix ...